How To Secure
Your Furniture
How To Strap Your Water Heater |
|
If you strap your water heater and
fit it with a flexible gas supply line, you will reduce the risk of a fire or explosion
from a gas leak after an earthquake. If your water heater does not have a flexible gas
supply line, contact a licensed plumber to install one.
These instructions are for installing a water heater restraint for a water heater on a
straight wall using the conduit method:
- Mark the water heater 9" down from the top and approximately 4" up from the
top of the controls. Locate the wood studs in the wall on both sides of the water heater.
- Using a stud finder or other appropriate methods, locate the closest stud behind and to
one side of the water heater.
- Transfer the marks on the water heater horizontally to the adjacent wall where the stud
identified in step 2 was located.
- Drill a 3/16" diameter -3" deep pilot hole at the marked location for the x
3" long lag screws.
- Measure around the water heater and add 2" to that measurement. Cut 2 pieces of 1
1/2" x 16 Gauge metal strap to the above measurement. Measure 1 1/2" from each
end of the strap and bend outward to an approximate right angle. Drill a 3/8" hole in
the bent ends to accommodate a 5/16" x 3/4" bolt and nut and mount loosely on
the water heater. The bolt/nut should be on the front of the unit.
- Using a straight stick, place the end at the hole in the wall with the side of the stick
against the side of the tape around the tank. Measure the distance from where the stick
touches the water heater to the hole in the wall. Add 1 1/2" to this measurement and
cut 1/2" diameter conduit to this length. Repeat this for each piece of conduit.
There may be two different measurements for the conduit due to the location of the studs.
- Using a hammer or vise, flatten 1" at each end of the 4 pieces of conduit. Be sure
to flatten both ends of each piece of conduit in the same plane.
- With the conduit in a vise, drill a 3/8" hole in one end of each conduit
approximately 1/2" from each end. Measure 1" from the end and bend up
approximately 45 degrees. This angle will have to be corrected slightly as the work
progresses. Hold the conduit on the wall with the hole in the conduit over the hole in the
wall, and mark the other end on the metal straps around the water heater and on the
conduit. Take down the conduit and drill a 3/8" hole at the mark for the bolt through
the flattened end of the conduit. Repeat for the conduit on the other side.
- Remove the straps around the tank and drill a 3/8" hole at the locations indicated
by the conduit. Loosely secure the straps to the tank and place a 5/16" x 3/4"
bolt through the hole in the strap. Place the conduit on the bolt protruding from the
strap and place a washer and nut on the bolt and tighten. Tighten the straps around the
tank at the correct locations. Position the opposite end of the conduit at the hole in the
wall and insert the lag screw with the washer and tighten. Do not drive the lag screw with
a hammer. It may be easier to do one side of the tank at a time because positioning the
tape can be difficult.
- Heater Safety Straps - If the water heater is not positioned within
1" of the wall, secure a 1" drywall (sheetrock) step spacer behind the water
heater to reduce the gap and to prevent excessive movement. This is normally one (or more)
piece(s) of of drywall within 9" of the top of the tank mounted to the rear wall
studs. Two small pieces of drywall are than fastened to the the first piece(s) to form a
cradle behind the tank. If the tank does rock, even with the strap on, it will strike the
sheetrock and not the wall - less damage to the wall and less to the tank.
- Repeat the above procedure for the rest of the conduits.
This is only one method of securing your hot water heater. There are now commercial
pre-engineered products available at your local building product supply store the
accomplish the same task.
MOA Recognized Bracing Assemblies
NOTE: The 1/4" x 1" bolts referred to in the above are known as 1/4" x
1" round head machine screws with a nut.
|